CASPER – Experimental boiler

Test and development of burners of semi-industrial scale.
Check of the atomizers efficiency.

• D-shape boiler
• Possible Flue Gas Recirculation
• Measurements windows on the side of the furnace

• The windows allow the use of any probes to measure the profiles of physical parameters inside the boiler.
Some of the quantities that can be measured are:
– Temperature
– Gas species composition
– Velocity field
– Radiation
• Measurements of the emissions chemical composition, in particular ultrafines particles.

Process Type

STEAM COOLED

Operating Pressure

ATMOSPHERIC

Orientation

HORIZONTAL

Shape

RECTANGULAR

Length

4.50

Width

165

Height

220

Thermal Capacity Min

1300.00kw

Thermal Capacity Max

6500.00kw

Processing Temperature

0.00

Processing Temperature Min

15.00

Type

Flame

Fuels (normally available)

Gasoil, Heavy Fuel Oil, Natural gas

Inflame/furnace measurements

CO, CO2, Gas temperature, NOx, O2